SHIPBOARD 1350W 1.55KVA TRUE On Line
Request a quote
PS3150rm2u is a low cost 1.5KVa true online UPS that supports a full 1350Watt load.
Description
Powerstar Shipboard Ready UPS since 1993
New Model! Powerstar shipboard PS3153rm2u AKA PS3150rm2u is a low cost 1.5KVa true online UPS that supports a full 1350Watt load. Large increase from previous models. Frequency converting if needed. This unit available in 2RU x 19.7″deep 120V or 230VAC International model. External port for additional battery packs. In use by US Navy. Made in US. Rugged versions available
Powerstar PS3150rm2u Low Profile True Online 1500VA UPS made in USA
NSN registered. 6130015760193
This unit can be ruggedized to MIL901D-B or MIL810
Double conversion type UPS wired for Delta power
Dual pole circuit breakers -No fuses
Dimensions 3.4″ x 17″ x 19.7″Deep
Supplied with a rack mounting kit (rails)
2 year warranty on all parts
The board / component manufacturer is certified to ISO 9001.
Frequency can be set to 50 or 60Hz or track the input frequency
Smart UPS tests itself and batteries periodically
Auto restart after a full run upon utility restoration
Cold Start capable
Field replaceable batteries through front panel while online
NOW! Output Power Capacity 1350 Watts @ .9pf / 1500 VA
Nominal Output Voltage 120V (configurable 100-127VAC) also available in 230VAC euro model.
Output Voltage Distortion Less than 3% at full load
Crest Factor up to 5: 1 Waveform Type Sine wave
Ready for Additional remotely mounted Battery trays with connector on back
Optional: Premium High temperature rated Flame proof Long Life (8-10 year) battery available.
Optional: This can be a 2ru X 28″deep rack mount unit with an input isolation transformer mounted to the rear. Or a separate Isolation transformer in a small box can be supplied if needed.
A 3ru x20″deep model is available with Isolation transformer.-PS3150rm3u-ISO
Output
(6) NEMA 5-15R
Military style or other connectors available.
> / = 3% total harmonic distortion (THD) typical into a 100% linear load, > / = 5% THD typical into a 100% non-linear load with crest factor ratio of 3:1.
>88% efficiency
Inverter Overload Capability: 200% for 10 seconds then transfer to bypass, 150% for 50 seconds then transfer to bypass
Voltage Transient Response: + 7% in line mode 0-100-0 % loading of the UPS,+ 7% in battery mode for 0-100-0 % loading of the UPS rating.
Transient Recovery Time: To nominal voltage within 90 milliseconds.
Output equipped with Automatic Bypass which connects input source to load should Inverter fail or load exceeds capacity of unit.
Input
Nominal Input Voltage 120V
Input Frequency 40/70 Hz (auto sensing)
Input Connections NEMA 5-15P
Cord Length 10 feet (3.04 meters)
Input voltage range for main operations 60 – 144V
Transfer Time 0 ms (Inverter is always running)
Input current rating 12A
Input Power Factor >.97 lagging at rated load
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leak proof AGM technology – cfr49 shippable
Typical recharge time 5 hours to 95%
Replacement Battery PSRBC3153-2u
High temperature long life (8-10 year) batteries available for this unit PSrbc3153-2u-h)
Typical Backup Time at Half Load -13 minutes
Typical Backup Time at Full Load -4 minutes
Typical Backup Time at 400W Load- 26 minutes
Runtime with 1 additional 2u battery pack 21″deep- PS3150rm2uBP or PS3150rm2uBP-H
Typical Backup Time at Half Load – >55 minutes
Typical Backup Time at Full Load -24 minutes
Typical Backup Time at 1100W Load -31 minutes
Interface Port(s)
DB-9 RS-232 with output shutdown pins and can interface with many PCs for shutdown
Available Slot Interface for SNMP Network Web card PS9059– Ethernet 10/100
Optional PS9059 SNMP v1, v2c with Http interface as well as Microlink software supplied
Control panel
LED status display with load and battery bar-graphs
Additional LEDS indicate UPS ON, Fault, On battery, Bypass mode enabled, AC input
Audible Alarm -Alarm when on battery: distinctive low battery alarm
Emergency Power Off (EPO)- Output can be disabled via shorting two pins in RS232 connector
Protection
UPS conforms to an input line transient conforming to IEEE C62.41, Category A & B tests for 120 VAC.
MOV ratings will be 175 Volt, 90 Joules minimum connected L1-L2. The MOVs will be rated 300 Volt, 150 Joules minimum connected L-G and L2-G. The L-G and L2-G connected MOVs will have the capability of being disconnected and reconnected easily.
Dimensions
Dimensions 3.4″ x 17″ x 19.7″Deep -28″deep with rear mounted Isolation transformer
This unit can be mounted on its side as a 17″tall tower. Mounting stand can be supplied.
Rack Height 2U
Net Weight 48.5 lbs.
Shipping Weight 58 lbs. (27 kg)
Shipping Height 8.00 inches
Shipping Width 30.00 inches
Shipping Depth 22 inches
Color Black
Mounting rails included for rack mounting
Operating Environment
32 – 104 °F (0 – 40 °C) (battery dependent) –This can be -20°C +50°C with our Premium battery upgrade.
Operating Relative Humidity 0 – 95%
Operating Elevation 0-10000 feet (0-3000 meters)
Storage Temperature 5 – 113 °F (-15 – 45 °C)
Storage Relative Humidity 0 – 95% °
Storage Elevation 0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit <46 dBA
2 year warranty on parts and Labor
Manufactured in the USA
Standards
UL Standard 1778 (Suitable for Computer-Room Applications)
• c-UL
• FCC Part 15, Subpart B, Class A
• IEEE C62.41, Category A & B
• CE for both Low Voltage and EMC Directives
• ISTA Procedure 1A
• Modified for Delta Shipboard power
Powerstar also offers this unit in a 3u case 20″deep with internal Isolation transformer-PS3150rm3u-ISO
800-209-5556 +1 301-948-0713; West coast + Australia contact +1925-270-0970
Powerstar Incorporated
9073 Shady Grove
Gaithersburg, MD 20877
Powerstar PS3153rm2u Low Profile True Online 1500VA UPS made in USA
NSN registered. 6130015760193
This unit can be ruggedized to MIL901D-B or MIL810
Double conversion type UPS wired for Delta power
Dual pole circuit breakers -No fuses
Dimensions 3.4″ x 17″ x 19.7″Deep
Supplied with a rack mounting kit (rails)
2 year warranty on all parts
The board / component manufacturer is certified to ISO 9001.
Frequency can be set to 50 or 60Hz or track the input frequency
Smart UPS tests itself and batteries periodically
Auto restart after a full run upon utility restoration
Cold Start capable
Field replaceable batteries through front panel while online
NOW! Output Power Capacity 1350 Watts @ .9pf / 1500 VA
Nominal Output Voltage 120V (configurable 100-127VAC) also available in 230VAC euro model.
Output Voltage Distortion Less than 3% at full load
Crest Factor up to 5: 1 Waveform Type Sine wave
Ready for Additional remotely mounted Battery trays with connector on back
Optional: Premium High temperature rated Flame proof Long Life (8-10 year) battery available.
Optional: This can be a 2ru X 28″deep rack mount unit with an input isolation transformer mounted to the rear. Or a separate Isolation transformer in a small box can be supplied if needed.
A 3ru x20″deep model is available with Isolation transformer.-PS3150rm3u-ISO
Output
(6) NEMA 5-15R
Military style or other connectors available.
> / = 3% total harmonic distortion (THD) typical into a 100% linear load, > / = 5% THD typical into a 100% non-linear load with crest factor ratio of 3:1.
>88% efficiency
Inverter Overload Capability: 200% for 10 seconds then transfer to bypass, 150% for 50 seconds then transfer to bypass
Voltage Transient Response: + 7% in line mode 0-100-0 % loading of the UPS,+ 7% in battery mode for 0-100-0 % loading of the UPS rating.
Transient Recovery Time: To nominal voltage within 90 milliseconds.
Output equipped with Automatic Bypass which connects input source to load should Inverter fail or load exceeds capacity of unit.
Input
Nominal Input Voltage 120V
Input Frequency 40/70 Hz (auto sensing)
Input Connections NEMA 5-15P
Cord Length 10 feet (3.04 meters)
Input voltage range for main operations 60 – 144V
Transfer Time 0 ms (Inverter is always running)
Input current rating 12A
Input Power Factor >.97 lagging at rated load
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leak proof AGM technology – cfr49 shippable
Typical recharge time 5 hours to 95%
Replacement Battery PSRBC3153-2u
High temperature long life (8-10 year) batteries available for this unit PSrbc3153-2u-h)
Typical Backup Time at Half Load -13 minutes
Typical Backup Time at Full Load -4 minutes
Typical Backup Time at 400W Load- 26 minutes
Runtime with 1 additional 2u battery pack 21″deep- PS3153rm2uBP or PS3153rm2uBP-H
Typical Backup Time at Half Load – >55 minutes
Typical Backup Time at Full Load -24 minutes
Typical Backup Time at 1100W Load -31 minutes
Interface Port(s)
DB-9 RS-232 with output shutdown pins and can interface with many PCs for shutdown
Available Slot Interface for SNMP Network Web card PS9059– Ethernet 10/100
Optional PS9059 SNMP v1, v2c with Http interface as well as Microlink software supplied
Control panel
LED status display with load and battery bar-graphs
Additional LEDS indicate UPS ON, Fault, On battery, Bypass mode enabled, AC input
Audible Alarm -Alarm when on battery: distinctive low battery alarm
Emergency Power Off (EPO)- Output can be disabled via shorting two pins in RS232 connector
Protection
UPS conforms to an input line transient conforming to IEEE C62.41, Category A & B tests for 120 VAC.
MOV ratings will be 175 Volt, 90 Joules minimum connected L1-L2. The MOVs will be rated 300 Volt, 150 Joules minimum connected L-G and L2-G. The L-G and L2-G connected MOVs will have the capability of being disconnected and reconnected easily.
Dimensions
Dimensions 3.4″ x 17″ x 19.7″Deep -28″deep with rear mounted Isolation transformer
This unit can be mounted on its side as a 17″tall tower. Mounting stand can be supplied.
Rack Height 2U
Net Weight 48.5 lbs.
Shipping Weight 58 lbs. (27 kg)
Shipping Height 8.00 inches
Shipping Width 30.00 inches
Shipping Depth 22 inches
Color Black
Mounting rails included for rack mounting
Operating Environment
32 – 104 °F (0 – 40 °C) (battery dependent) –This can be -20°C +50°C with our Premium battery upgrade.
Operating Relative Humidity 0 – 95%
Operating Elevation 0-10000 feet (0-3000 meters)
Storage Temperature 5 – 113 °F (-15 – 45 °C)
Storage Relative Humidity 0 – 95% °
Storage Elevation 0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit <46 dBA
2 year warranty on parts and Labor
Manufactured in the USA
Standards
UL Standard 1778 (Suitable for Computer-Room Applications)
• c-UL
• FCC Part 15, Subpart B, Class A
• IEEE C62.41, Category A & B
• CE for both Low Voltage and EMC Directives
• ISTA Procedure 1A
• Modified for Delta Shipboard power
Powerstar also offers this unit in a 3u case 20″deep with internal Isolation transformer-PS3150rm3u-ISO