PS3200rm3u mil 461 filter True Online 2000VA UPS tested at nulabs  navy tested

NSN registered.

 Double conversion type UPS wired for Delta power

Dual pole circuit breakers -No fuses

Dimensions 3.4” x 17” x ”Deep with iso added depth change

Supplied with a rack mounting kit (rails)

2 year warranty on all parts

The board / component manufacturer is certified to ISO 9001.

ISO/TRAN 2kva isolated (optional)

Frequency can be set to 50 or 60Hz or track the input frequency

Smart UPS tests itself and batteries periodically

Auto restart after a full run upon utility restoration

Cold Start capable

Field replaceable batteries through front panel while online including premium batteries

NOW! Output Power Capacity 1800 Watts @ .9pf  / 2000 VA  mil 461 filters filter conceps and captor filter

Nominal Output Voltage 120V (configurable 100-127VAC)  also available in 230VAC euro model.

Output Voltage Distortion Less than 3% at full load

Crest Factor up to 5: 1 Waveform Type Sine wave

Ready for Additional remotely mounted Battery trays with connector on back

Optional: Premium High temperature rated Flame proof Long Life (8-10 year) battery available.

Optional: This can be a 2ru X 28”deep rack mount unit with an input isolation transformer mounted to the rear. Or a separate Isolation transformer in a small box can be supplied if needed.

A 3ru x20”deep model is available with Isolation transformer.-PS32000rm3u-ISO

Optional mil 461 filtering

Output

(6) NEMA 5-15R  or mil connectors

 Military style or other connectors available.

> / = 3% total harmonic distortion (THD) typical into a 100% linear load, > / = 5% THD typical into a 100% non-linear load with crest factor ratio of 3:1.

>88% efficiency

Inverter Overload Capability: 200% for 10 seconds then transfer to bypass, 150% for 50 seconds then transfer to bypass

Voltage Transient Response: + 7% in line mode 0-100-0 % loading of the UPS,+ 7% in battery mode for 0-100-0 % loading of the UPS rating.

Transient Recovery Time: To nominal voltage within 90 milliseconds.

Output equipped with Automatic Bypass which connects input source to load should Inverter fail or load exceeds capacity of unit.

Input

Nominal Input Voltage 120V

Input Frequency 40/70 Hz  (auto sensing)

Input Connections NEMA 5-15P or mil connectors

Cord Length 10 feet (3.04 meters)

Input voltage range for main operations 60 - 144V

Transfer Time 0 ms (Inverter is always running)

Input current rating 20A

Input Power Factor >.97 lagging at rated load

hitemp longlife battery included

 

Batteries & Runtime

Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leak proof AGM technology - cfr49 shippable

Typical recharge time 5 hours to 95%

Replacement Battery PSRBC3153-2u

High temperature long life (8-10 year) batteries available for this unit PSrbc3153-2u-h)

Typical Backup Time at Half Load -13 minutes

Typical Backup Time at Full Load -4 minutes

Typical Backup Time at 400W Load- 26 minutes

 

Load in W

400W

600W

800W

1000W

1200W

1350W

PS32000rm3u

26

16

10

8

5

4 minutes

+1 PS32000BP

110

72

48

36

28

24 minutes

 

 

Runtime with 1 additional 2u battery pack 21”deep- PS3200rm2uBP or PS3200rm2uBP-H

Typical Backup Time at Half Load - >55 minutes 

Typical Backup Time at Full Load -24 minutes

Typical Backup Time at 1100W Load -31 minutes

 

Interface Port(s)

DB-9 RS-232 with output shutdown pins and can interface with many PCs for shutdown

Available Slot Interface for SNMP Network Web card PS9059- Ethernet 10/100

Optional PS9059 SNMP v1, v2c with Http interface as well as Microlink software supplied

 

Control panel

LED status display with load and battery bar-graphs

Additional LEDS indicate UPS ON, Fault, On battery,  Bypass mode enabled, AC input

Audible Alarm -Alarm when on battery: distinctive low battery alarm

Emergency Power Off (EPO)- Output can be disabled via shorting two pins in RS232 connector

 

Protection

UPS conforms to an input line transient conforming to IEEE C62.41, Category A & B tests for 120 VAC. Including isolation transformer

MOV ratings will be 175 Volt, 90 Joules minimum connected L1-L2. The MOVs will be rated 300 Volt, 150 Joules minimum connected L-G and L2-G. The L-G and L2-G connected MOVs will have the capability of being disconnected and reconnected easily.

 

Dimensions

Dimensions 3.4” x 17” x 19.7”Deep -28”deep with rear mounted Isolation transformer

This unit can be mounted on its side as a 17”tall tower. Mounting stand can be supplied.

Rack Height 2U

Net Weight 48.5 lbs. 

Shipping Weight 58 lbs. (27 kg)

Shipping Height 8.00 inches

Shipping Width 30.00 inches 

Shipping Depth 22 inches

Color Black

Mounting rails included for rack mounting

 

Operating Environment

32 - 104 °F (0 - 40 °C)  (battery dependent) -This can be -20°C +50°C  with our Premium battery upgrade.

Operating Relative Humidity 0 - 95%

Operating Elevation 0-10000 feet (0-3000 meters)

Storage Temperature 5 - 113 °F (-15 - 45 °C)

Storage Relative Humidity 0 - 95% °

Storage Elevation 0-50000 feet (0-15000 meters)

Audible noise at 1 meter from surface of unit  <46 dBA

2 year warranty on parts and Labor

Manufactured in the USA

 

 

Standards

UL Standard 1778 (Suitable for Computer-Room Applications)

• c-UL

• FCC Part 15, Subpart B, Class A

• IEEE C62.41, Category A & B

• CE for both Low Voltage and EMC Directives

• ISTA Procedure 1A

• Modified for Delta Shipboard power

 

Powerstar also offers this unit in a 3u case 20”deep with internal Isolation transformer-PS3150rm3u-ISO

 

http://www.powerstarinc.com

800-209-5556     +1 301-948-0713

Powerstar Incorporated

9073 Shady Grove

Gaithersburg, MD 20877

 

With optional mil connectors


or mil connectors

 

PS3200rm2ui with external battery connector, (1) C14, (6) C13 connectors for 230VAC